China SK water ring vacuum pump

Before installing the China SK water ring vacuum pump,a series of preparatory work needs to be carried out.Firstly,the pump and its accessories should be checked for integrity,especially key components such as the pump body,impeller,and bearings.Secondly,for vacuum pumps that have been stored for too long,the lubricating grease in the pump bearing chamber should be replaced before starting,and the bearing chamber should be cleaned with gasoline.In addition,it is necessary to loosen the packing gland and squeeze a small amount of ordinary engine oil into the packing for lubrication.

China SK water ring vacuum pump

Entering the formal installation phase,the first step is to install the China SK water ring vacuum pump on the pump seat to ensure that the pump body is stable and level.During installation,the concentricity between the motor shaft and the pump shaft should be corrected to avoid bearing heating and component wear caused by slight tilting.At the same time,attention should be paid to the connection with equipment such as compressors to ensure that the connecting pipelines are short and have few bends,in order to reduce flow loss and exhaust resistance.
When installing the air-water separator,it should be installed on the foundation according to the outline drawing.The connection pipeline between the separator and the China SK water ring vacuum pump should avoid excessively long and sharp turns as much as possible to ensure smooth flow of the gas water mixture in the pipeline.In addition,gate valves or one-way valves need to be installed on the exhaust pipeline of the gas water separator to prevent gas from returning to the system and affecting the normal operation of the vacuum pump.
Before connecting the power supply,ensure that its steering direction is in accordance with the specified direction to prevent rotation and fuel injection.At the same time,valves and vacuum gauges need to be installed above the inlet of the SK type water ring vacuum pump in China to check the pressure of the vacuum pump at any time.For vacuum pumps that require cooling,cooling water should also be connected according to the rules to ensure that the vacuum pump will not be damaged due to overheating during operation.
After installation,further debugging work is required.Firstly,the valve on the water supply pipe should be opened to gradually increase the water supply until it meets the specified requirements.Then,open the gate valve on the intake pipeline to allow the China SK water ring vacuum pump to start working normally.During the debugging process,the operating sound,bearing temperature,and water supply of the vacuum pump should be observed to ensure that they are within the normal range.
The installation process of China SK type water ring vacuum pump needs to strictly follow the operating specifications to ensure that each step is accurate and error free.Only in this way can the vacuum pump ensure its performance during normal operation and provide stable and reliable power support for industrial production.